delta_servo [2019/01/08 13:14] – emozolyak | delta_servo [2019/01/08 13:16] – emozolyak |
---|
| **03-06** | 03-06 (HR30C) defines the source for the digital inputs of the drive - wether they are "real" external inputs, or 'force' values got via Modbus. Bits 0..7 of this paramter corresponds to real digital inputs DI1..DI8. Writing 0 sets "real" mode, 1 - 'force' input from Modbus paramter 4-07 (HR40E) (it is a bit mask). | | | **03-06** | 03-06 (HR30C) defines the source for the digital inputs of the drive - wether they are "real" external inputs, or 'force' values got via Modbus. Bits 0..7 of this paramter corresponds to real digital inputs DI1..DI8. Writing 0 sets "real" mode, 1 - 'force' input from Modbus paramter 4-07 (HR40E) (it is a bit mask). | |
| |
Modbus адреса всех параметров указаны в описании каждого пользовательского параметра, вместе с типом данных и диапазоном возможных значений: | Modbus adresses of all parameters are provided in the manual with its datatype and valid range: |
| |
{{ ::mb_map_servo.png?direct&600 |}} | {{ ::mb_map_servo.png?direct&600 |}} |