Line 6: | Line 6: | ||
The parameters to be set: | The parameters to be set: | ||
- | * 8-01 = 2 (source of control CTW only) | + | * 8-01 = 2 (source of control CTW only) |
- | * 8-02 = 1 (source of CTW is from RS-485) | + | * 8-02 = 1 (source of CTW is from RS-485) |
* 8-04 = 0 (disable comm. timeout) | * 8-04 = 0 (disable comm. timeout) | ||
- | * 8-30 = 2 (Modbus RTU protocol selection) | + | * 8-30 = 2 (Modbus RTU protocol selection) |
* 8-31 = 1 (slaveId) | * 8-31 = 1 (slaveId) | ||
- | * 8-32 = 2 (9600 comm. speed) | + | * 8-32 = 2 (9600 comm. speed) default is 3 (19200) |
- | * 8-33 = 2 (no parity, one stop bit) | + | * 8-33 = 2 (no parity, one stop bit) default is 0 even parity |
To save the parameters to EEPROM the 64 (decimal) register should be in 1. | To save the parameters to EEPROM the 64 (decimal) register should be in 1. |