 |Error run hours| ERH0                         | hours | |Error run hours| ERH0                         | hours |
  
-  The driver return integer values. You should scale them appropriately to get exact values using Multiplier field +  The driver returns integer values. You should scale them appropriately to get exact values using Multiplier field 
   in register properties.   in register properties.
      
Line 40: Line 40:
  
 Before testing the protocol in the field, it's preferrable to test it in a lab (if you have a meter on-hand).  Before testing the protocol in the field, it's preferrable to test it in a lab (if you have a meter on-hand). 
-To simulate temperatures you can use resistors or potentiometers, ~ 500 Ohm, резистор обратки должен быть меньше, чтобы разница температур составила более градусов (тогда будет работать счетчик энергии). Импульсы можно подать кнопкой, замыкая контакты 10-11. +To simulate temperatures you can use resistors or potentiometers, note that return temperature have to be less than forward for or more degrees (otherwise energy won't work). Flowmeter can be simulated by shorting 10-11 pins of i/o board
  
-{{ ::scylar_conn2.png?direct&400 |}}+== Custom protocol (driver) code block == 
 + 