 In a __very large systems__, there are sometimes hundreds of devices (usually identical), with hundreds of even thousands of registers in each of them. If all these parameters were declared in a WebHMI register list, this would heavily load the system, increase scan time, increase processing time etc.  In a __very large systems__, there are sometimes hundreds of devices (usually identical), with hundreds of even thousands of registers in each of them. If all these parameters were declared in a WebHMI register list, this would heavily load the system, increase scan time, increase processing time etc. 
  
-{{::many_devices.png?direct&400|}}+{{network:many_devices.png?direct&400|}}
  
 In fact, each device has only few parameters to monitor - regarding object being monitored itself, while the rest (and most) are just settings like delays, hysteresys, scaling coefficients, sensors types and so on, being rarely accessed. In fact, each device has only few parameters to monitor - regarding object being monitored itself, while the rest (and most) are just settings like delays, hysteresys, scaling coefficients, sensors types and so on, being rarely accessed.
Line 15: Line 15:
 This task can be easily built with WebHMI tools - dashboards and scripts. The idea is illustrated in the below figure: This task can be easily built with WebHMI tools - dashboards and scripts. The idea is illustrated in the below figure:
  
- {{::optimize_option_1.png?direct&640|}}+ {{network:optimize_option_1.png?direct&800|}}
  
 Each device (temperature controller) has two main parameters: process value and setpoint, that's enough for process control. There is also a bunch of "unwanted for constant scan" setting registers 1..100. We want to access "unwanted" registers on-demand, not interfering main scan where more importand data is placed.  Each device (temperature controller) has two main parameters: process value and setpoint, that's enough for process control. There is also a bunch of "unwanted for constant scan" setting registers 1..100. We want to access "unwanted" registers on-demand, not interfering main scan where more importand data is placed. 