delta_servo [2019/01/08 13:14] – emozolyak | delta_servo [2019/01/08 13:21] – emozolyak |
---|
| **03-06** | 03-06 (HR30C) defines the source for the digital inputs of the drive - wether they are "real" external inputs, or 'force' values got via Modbus. Bits 0..7 of this paramter corresponds to real digital inputs DI1..DI8. Writing 0 sets "real" mode, 1 - 'force' input from Modbus paramter 4-07 (HR40E) (it is a bit mask). | | | **03-06** | 03-06 (HR30C) defines the source for the digital inputs of the drive - wether they are "real" external inputs, or 'force' values got via Modbus. Bits 0..7 of this paramter corresponds to real digital inputs DI1..DI8. Writing 0 sets "real" mode, 1 - 'force' input from Modbus paramter 4-07 (HR40E) (it is a bit mask). | |
| |
Modbus адреса всех параметров указаны в описании каждого пользовательского параметра, вместе с типом данных и диапазоном возможных значений: | Modbus adresses of all parameters are provided in the manual with its datatype and valid range: |
| |
{{ ::mb_map_servo.png?direct&600 |}} | {{ ::mb_map_servo.png?direct&600 |}} |
| |
Например,в режиме управления по скорости , когда дискретные входы SPD1 и SPD0 не равны 00, комбинация этих входов определяет из какого регистра будет задаваться скорость, а скорости S2,S3,S4 в свою очередь записаны в параметрах 1-09,1-10,1-11 (регистры Modbus HR112,HR114,HR116). Подробно режимы управления приводом с адресами Modbus приведены в руководстве пользователя ASDA-B2. | |
| |