Line 20: Line 20:
   ***REF** Bus reference register - frequency setpoint HR50009   ***REF** Bus reference register - frequency setpoint HR50009
   ***STW** status word - accessible bitwise on C32..C47 addresses with Read coils or HR50199 with holding register read   ***STW** status word - accessible bitwise on C32..C47 addresses with Read coils or HR50199 with holding register read
-  **MAV** actual frequency HR50209.+  ***MAV** actual frequency HR50209.
  
 More details on working with Danfoss FC drives are described in document MG.02.A4.02 VLT® Micro Drive FC 51 Operating Instructions. Below is a table with parameters. The parameter numbers specified in these tables must be specified in the register settings with an offset of -1. For example, the Bus reference register (REF) in the documentation has the address 50000, but in the WebHMI you set it as HR49999. More details on working with Danfoss FC drives are described in document MG.02.A4.02 VLT® Micro Drive FC 51 Operating Instructions. Below is a table with parameters. The parameter numbers specified in these tables must be specified in the register settings with an offset of -1. For example, the Bus reference register (REF) in the documentation has the address 50000, but in the WebHMI you set it as HR49999.
Line 36: Line 36:
 In the frequency converter, the frequency values are presented as follows: the frequency 50 Hz (100% of the scale) corresponds to the number 16384. Negative values are also a number in binary complementary form (two's complement). Therefore, to correctly display the frequency and its task for the registers, it is necessary to use the multiplier 50/16384 = 0.0030517578125, and specify the appropriate format in the register properties. In the frequency converter, the frequency values are presented as follows: the frequency 50 Hz (100% of the scale) corresponds to the number 16384. Negative values are also a number in binary complementary form (two's complement). Therefore, to correctly display the frequency and its task for the registers, it is necessary to use the multiplier 50/16384 = 0.0030517578125, and specify the appropriate format in the register properties.
  
-По [[ https://www.youtube.com/watch?v=iU3dzC1dQ4E | ссылке ]] доступно видео (in Russian language) с демонстрацией управления частотным приводом Danfoss, а также управление холодильным контроллером Danfoss AK-CC 550.+There is a [[ https://www.youtube.com/watch?v=iU3dzC1dQ4E | video ]] (in Russian language) with live demo of controlling Danfoss FCS 51and cooling controller Danfoss AK-CC 550 as well.