Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision |
configuration_reset [2019/01/08 12:18] – [WebHMI Reset method (from networking menu)] emozolyak | configuration_reset [2019/01/08 12:27] – [Configuration reset] emozolyak |
---|
====== Configuration reset ====== | ====== Configuration reset ====== |
| |
There are two parts of the WebHMI's configuration - Project configuration and Network configuration. The project configuration essentially is the 'HMI' part, which defines how the project runs and looks for the users, while Network configuration defines settings of the WebHMI's communication interfaces enabling access from/to external devices. | There are two parts of the WebHMI's configuration - __Project__ configuration and __Network__ configuration. The project configuration essentially is the 'HMI' part, which defines how the project runs and looks for the users, while Network configuration defines settings of the WebHMI's communication interfaces enabling access from/to external devices. |
| |
*Project configuration reset - can be made in 2 ways: from the project itself ( Setup / Clean project menu), or from the network configuration ( WebHMI / Reset menu) | *Project configuration reset - can be made in 2 ways: from the project itself ( Setup / Clean project menu), or from the network configuration ( WebHMI / Reset menu) |
===== Network settings reset ===== | ===== Network settings reset ===== |
| |
To reset the network settings, press and hold the 'Reset' button (located on the front panel of the device) when the device is turned on. After a while (approximately after 20-30 seconds, depending on the version of the firmware maybe longer) the red 'Error' LED will flash. Continue to hold down the 'Reset' button. After the first flashing, the 'Error' LED goes out and then lights up for a few seconds again. | To reset the network settings, press and hold the 'Reset' button (located on the front panel of the device) when the device is turned on. |
| |
| {{ ::net_conf_button.png?direct&200 |}} |
| |
| After a while (approximately after 20-30 seconds, depending on the version of the firmware maybe longer) the red 'Error' LED will flash. Continue to hold down the 'Reset' button. After the first flashing, the 'Error' LED goes out and then lights up for a few seconds again. |
| |
At this point, the 'Reset' button can already be released. The cleaning operation may take several seconds or more. After reset, the system will reboot again to apply the new settings. | At this point, the 'Reset' button can already be released. The cleaning operation may take several seconds or more. After reset, the system will reboot again to apply the new settings. |